Why the backflow preventer is so vulnerable

Colorado irrigation systems connected to household water normally include a backflow prevention device so that lawn water cannot be drawn back into the drinking supply. On many Parker lots that device is a pressure vacuum breaker or a reduced pressure assembly standing above ground near the foundation, fed by a pipe that leaves the basement or crawl space through the wall.

It is made of brass and bronze castings with internal chambers that hold water, and it sits fully exposed to wind. When a hard freeze arrives before the system has been shut off and drained, the water inside expands and can crack the body, pop a bonnet, or split the copper riser. Parker sometimes sees its first hard freeze while lawns are still green, which is exactly when owners tend to put off winterizing.

The damage is usually outdoors, but not always. If the irrigation shutoff inside the house was left open, a split riser can push water back along the foundation, and a cracked line inside the wall can leak into a finished basement.

Where an irrigation freeze shows up

Locations vary by builder; trace your own system from the indoor shutoff outward.
LocationWhat failure looks likeWho usually handles it
Backflow device above groundWater spraying from a cracked body or a bonnet that has liftedIrrigation technician or plumber
Copper risers into the groundSplit along the pipe just above the soil lineIrrigation technician
Pipe through the foundation wallDamp drywall or carpet on the inside of the wall near the devicePlumber, then drying if the interior is wet
Indoor irrigation shutoff and drainDrip or seep at the valve in a mechanical room or under stairsPlumber
Underground lines and valvesSoft, soggy patches or water bubbling up in springIrrigation technician

Before a forecast hard freeze

  1. Close the indoor irrigation valve

    Find the shutoff where the irrigation line branches from household plumbing, usually in the basement or crawl space, and close it.

  2. Drain what you can

    Open the small drain or test cocks on the backflow device per its type so water can escape. If unsure, leave it to a technician.

  3. Schedule the blowout

    Compressed-air winterization clears the zones. It is commonly done by an irrigation company because too much pressure can damage parts.

  4. Insulate if you must wait

    An insulated bag over the device can buy a night or two, but it is not a substitute for draining.

Questions for an irrigation technician after a freeze

  1. Did the device body crack, or only a replaceable part such as a bonnet or poppet?
  2. Does the replacement need to be tested and the result reported to the water provider?
  3. Is the indoor shutoff holding fully, or does it seep when closed?
  4. Would an insulated enclosure or a different device location reduce the risk next fall?
  5. Is the pipe through the foundation wall sealed so cold air is not reaching indoor lines?